CELLAR COOLING SYSTEMS
The Range Consisting of compact BMO outdoor, weatherproof, housed units aligned with space saving BMI evaporators, the Beermaster range is the solution to all cellar cooling applications. Operating two BMI evaporators will successfully cool cellars with irregular shapes (with one BMO condensing unit). Temperature is controlled from one evaporator, the other acting as a slave unit. Beermaster BMO condensing units are designed to minimise sound levels, which together with an acoustic kit option enables a further 6dB(A) reduction, in noise sensitive locations. The BMI evaporator compact design incorporates an external rotor fan set, reducing sound, resonance and vibration, therefore minimising sound break out into bar and accommodation areas.
BMO Condensing Unit Specification Nominal sound pressure levels:41 to 49dB(A)at 10m. Lower sound levels are achieved using the acoustic kit. Housing: Fully weatherproof, with powder coate grey gloss finish (RAL7036). Compressor: BM 100 - Hermetic complete with crankcase heater. BM0120 to 550 - Scroll complete with crankcase heater Liquid Line: Receiver and sightglass. Controls: Externally accessible mains isolator, Contactor. HP and LP pressure switches. Fully wired and enclosed electrical assembly Fansetss: Single phase, high efficiency, low noise, external rotor design, rated to IP44. Service: Maximum access for service maintenance. Simple hinged and removable panels. Lid lifts up and latches, with two positions - full open or front access only. Connections: Liquid and Suction angle service valves, pr-fitted with solder adaptors. External charging/guage access ports. Installation: Easy brazing to unit connections, Access without need to remove fixings. All components fully accessible from one side.
BMI Evaporator Specification Nominal Sound Pressure Levels: 53 to 58dB(A) at 3m. Construction: Compact steel chassis design. White, single piece highly durable ABS front panel, incorporating fan mounting and controls. Drain Tray: Durable ABS with 3/4 inch BSP connection. Simple removal for cleaning. Fittings easily available to connect to speedfit, copper, polypipe, etc. as a standard drain fitting. Controls: Electronic controller, mounted in a sub assembly with the fan capacitors and pre-made wiring connections. Incorporates an off cycle defrost regime, which automatically initiates if the optional defrost sensor is fitted. Expansion valve and solenoid valve. Fansets: Single phase, high efficiency, low noise external rotor design, rated to IP44 complete with air straightener. Air Throw: Up to 17m for even cellar temperatures. Energy Saving: Option to operate twin and three fan evaporators on a single fan during off cycle or heating mode. An off cycle defrost will initiate all fans. Air Heater: Single fan - 1.1 kw, twin/triple fan - 2.2kw, operated by controller, which incorporates a dead band control. Liquid Line: Inlet connection with filter drier and solenoid valve. Service: Front panel, drain tray, and end panels are fully removable providing full access to unit, without the need to release from ceiling or wall brackets. Front mounted controller allows access without removing platework. Connections: End plates wrap around back of evaporator. Removal provides full access to the pipework connections. Installation: Easily accessible endplates. All components fully accessible from one side.
Options Wall bracket: Universal design suitable for for all BMO condensing units and BMI evaporators Acoustic Kit: Minimum sound pressure levels are achieved on the BMO condensing units using this option, with reductions up to 6 dB(A) at 10m, when running the fan at minimum speed. The kit comprises the fan speed controller and acoustic lining to the compressor compartment. Defrost Sensor: Required on all cellar selections at 4° and some at 8°, as indicated in the selection data. Electronic controller incorporates an off cycle defrost regime, which automatically initiates if the defrost sensor is fitted